Your personal benefit:
SIKORA’s SPARK testers reliably detect punctual faults and bare spots in the insulation of wires and cables. The test voltage is adjustable. In this way, the systems guarantee the highest product quality and ensure that only fault-free cables are delivered. The SPARK devices comply with the most important testing standards (IEC, UL) and safety regulations according to IEC60479-1.

Specifications

DeviceSPARK 60 ACSPARK 100 ACSPARK 140 ACSPARK 200 ACSPARK 20 DCSPARK 30 ULSPARK 30 HF
Product diameter1,0 to 60 mm1,0 to 100 mm1,0 to 140 mm1,0 to 200 mm1,0 to 20 mmup to 30 mmup to 30 mm
Test voltage1,6…25 kV (30/35 kV optional)1,6…25 kV (30/35 kV optional)1,6…25 kV (30/35 kV optional)1,6…25 kV (30/35 kV optional)1,0 to 20 kV DC1,0 to 15 kV (RMS)1,0 to 15 kV (RMS)
Integrated display----Yes-Yes
Integrated self-test------Yes (optional)
InterfacesRS485, RS232, Analog input and output test voltage, potential free contacts, Ethernet/UDP Optional Spark HF/DC/AC: Profibus-DP, Profinet, EtherNet/IP, CANopen, DeviceNet, EtherCAT Optional SPARK UL: Profibus-DP, ProfinetRS485, RS232, Analog input and output test voltage, potential free contacts, Ethernet/UDP Optional Spark HF/DC/AC: Profibus-DP, Profinet, EtherNet/IP, CANopen, DeviceNet, EtherCAT Optional SPARK UL: Profibus-DP, ProfinetRS485, RS232, Analog input and output test voltage, potential free contacts, Ethernet/UDP Optional Spark HF/DC/AC: Profibus-DP, Profinet, EtherNet/IP, CANopen, DeviceNet, EtherCAT Optional SPARK UL: Profibus-DP, ProfinetRS485, RS232, Analog input and output test voltage, potential free contacts, Ethernet/UDP Optional Spark HF/DC/AC: Profibus-DP, Profinet, EtherNet/IP, CANopen, DeviceNet, EtherCAT Optional SPARK UL: Profibus-DP, ProfinetRS485, RS232, Analog input and output test voltage, potential free contacts, Ethernet/UDP Optional Spark HF/DC/AC: Profibus-DP, Profinet, EtherNet/IP, CANopen, DeviceNet, EtherCAT Optional SPARK UL: Profibus-DP, ProfinetRS485, RS232, Analog input and output test voltage, potential free contacts, Ethernet/UDP Optional Spark HF/DC/AC: Profibus-DP, Profinet, EtherNet/IP, CANopen, DeviceNet, EtherCAT Optional SPARK UL: Profibus-DP, ProfinetRS485, RS232, Analog input and output test voltage, potential free contacts, Ethernet/UDP Optional Spark HF/DC/AC: Profibus-DP, Profinet, EtherNet/IP, CANopen, DeviceNet, EtherCAT Optional SPARK UL: Profibus-DP, Profinet
Power supply100 - 240 V AC ± 10 %, 50/60 Hz100 - 240 V AC ± 10 %, 50/60 Hz100 - 240 V AC ± 10 %, 50/60 Hz100 - 240 V AC ± 10 %, 50/60 Hz100 - 240 V AC ± 10 %, 50/60 Hz100 - 240 V AC ± 10 %, 50/60 Hz100 - 240 V AC ± 10 %, 50/60 Hz